Capacitance range: 1000 pF to 0.047 µF (E12-values on request) Rated voltages: 100VDC, 250VDC, 400VDC Capacitance tolerances: ±20%, ±10%, ±5% Operating temperature range: -55°C to +100°C Test specifications: In accordance with IEC 60384-11 Climatic test category: 55/100/56 in accordance with IEC Insulation resistance at +20°C: > 3 x 104 M (mean value: 8 x 105 M ) Measuring voltage: 100 V/1 min. Test voltage: 2 Ur, 2 sec Maximum pulse rise time: 1000 V/µsec for pulses equal to the rated voltage |
 |
Dissipation factors at +20°C: tan |
at f |
C < 0.047 µF |
1kHz 10kHz 100kHz |
< 7 x 10-3 < 15 x 10-3 < 20 x 10-3 |
|
Voltage derating: A voltage derating factor of 1.25% per K must be applied from +85°C for DC voltages and from +75°C for AC voltages. Reliability: Operational life > 300000 hours Failure rate < 5 fit (0.5 x Ur and 40°C) |
|