Capacitance range: 1000 pF to 0.022 µF (E12-values on request) Rated voltages: 100VDC, 250VDC, 400VDC Capacitance tolerances: ±20%, ±10%, ±5% (±2.5% available subject to special enquiry) Operating temperature range: -55°C to +100°C Climatic test category: 55/100/56 in accordance with IEC Insulation resistance at +20°C: > 5 x 105 M (mean value: 1 x 106 M ) Measuring voltage: 100 V/1 min. Test voltage: 2 Ur, 2 sec Dissipation factors at +20°C: tan |
at f |
C < 0.022 µF |
1kHz 10kHz 100kHz |
< 3 x 10-3 < 5 x 10-3 < 8 x 10-3 |
|
Maximum pulse rise time: 1000 V/µsec for pulses equal to the rated voltage |
|
 |
Capacitance change versus temperature (f = 1kHz) (general guide) |
|
Voltage derating: A voltage derating factor of 1.35% per K must be applied from +85°C for DC voltages and from +75°C for AC voltages. Reliability: Operational life > 300000 hours Failure rate < 5 fit (0.5 x Ur and 40°C) |
|